Product Details
We can deliver for all measurement problems suitable sensors and transducers. Besite the listed sensors and transducers you find further in our price list. Feel free to contact us for the price list and information for not listed sensors and transducers.
Technical Specifications
METEOROLOGIC SENSORS
Windspeed sensor cupstar anemometer with heating, range 0,5 to 50 m/s, accuracy ± 3 % from rdg. or 0,5 m/s, output 0 to 10 V or 4 to 20 mA
Wind direction, wind vane with heating, range 0° to 360°, resolution 11,25°, accuracy ± 5 % from rdg., output 0 to 10 V or 4 to 20 mA
Ambient temperature sensor with IP 65 polycarbonat case, Pt100, accuracy class B corresponding to DIN EN 60751
Module temperature sensor, Pt100, accuracy class B corresponding to DIN EN 60751, self adhesive, 2 m cable
Other Sensors you can take out of our price list or contact us.
TRANSDUCER
UgT-MU(-DC) Transducer for DC voltages from 0 to 5 mV up to 0 to 600 V, double output with 0 to 20 mA and 0 to 10 V, accuracy ± 0,5 %, voltage supply 230 VAC (24 VDC)
IgT-MU(-DC) Transducer for DC currents from 0 to 100 ľA up to 0 to 5 A, double output with 0 to 20 mA and 0 to 10 V, accuracy ± 0,5 %, voltage supply 230 VAC (24 VDC)
Iw-MU Transducer for sinoidial currents of 1 or 5 A, output 0 to 20 mA, accuracy ± 0,5 %
Dlw-MU Transducer for sinoidial currents of 50 A, with hall effect, output 0 to 20 mA, accuracy ± 0,5 %
PGs-MU(-DC) Transducer for DC power or multiplication of two voltages, current input with external shunt, voltages between 0 to 10 V and 0 to 500 V, double output with 0 to 20 mA and 0 to 10 V, accuracy ± 0,5 %, voltage supply 230 VAC (24 VDC)
EZW Transducer for AC power and energy (one phase), acquisition of consumption and delivery, current input of 5 A (in conjunction with current transformer 40 different primary currents up to 4000 A adjustable), voltage 230 V, single output with 0 to 20 mA for the power, 2 impulse output (1 to 500 Imp/kWh) for energy consumption and delivery, internal LCD for energy and power, accuracy ± 0,5% (power) and ± 1% (energy)
EZD Transducer for AC power and energy (three phases), voltage 400/230 V, other characteristics as EZW
ELT-Z Energy counter for one phase AC, current input of 5(20) A, impulse output (1.000Imp/kWh) for energy, internal 6 digit electromechanical counter, accuracy ± 1%, mounting od DIN rail
Pt-MU(-DC) Transducer for Pt100 sensor for 0 to 60 °C, 0 to 100 °C, 0 to 150 °C, 0 to 300 °C or 0 to 600 °C (other values on request, double output with 0 to 20 mA and 0 to 10 V, accuracy ± 0,5 %, voltage supply 230 VAC (24 VDC)