Other Sensors and Transducers


Product Details
We can deliver for all measurement problems suitable sensors and transducers. Besite the listed sensors and transducers you find further in our price list. Feel free to contact us for the price list and information for not listed sensors and transducers.

Technical Specifications

METEOROLOGIC SENSORS

Windspeed sensor cupstar anemometer with heating, range 0,5 to 50 m/s, accuracy ± 3 % from rdg. or 0,5 m/s, output 0 to 10 V or 4 to 20 mA

Wind direction, wind vane with heating, range 0° to 360°, resolution 11,25°, accuracy ± 5 % from rdg., output 0 to 10 V or 4 to 20 mA

Ambient temperature sensor with IP 65 polycarbonat case, Pt100, accuracy class B corresponding to DIN EN 60751

Module temperature sensor, Pt100, accuracy class B corresponding to DIN EN 60751, self adhesive, 2 m cable

Other Sensors you can take out of our price list or contact us.

TRANSDUCER

UgT-MU(-DC) Transducer for DC voltages from 0 to 5 mV up to 0 to 600 V, double output with 0 to 20 mA and 0 to 10 V, accuracy ± 0,5 %, voltage supply 230 VAC (24 VDC)

IgT-MU(-DC) Transducer for DC currents from 0 to 100 ľA up to 0 to 5 A, double output with 0 to 20 mA and 0 to 10 V, accuracy ± 0,5 %, voltage supply 230 VAC (24 VDC)

Iw-MU Transducer for sinoidial currents of 1 or 5 A, output 0 to 20 mA, accuracy ± 0,5 %

Dlw-MU Transducer for sinoidial currents of 50 A, with hall effect, output 0 to 20 mA, accuracy ± 0,5 %

PGs-MU(-DC) Transducer for DC power or multiplication of two voltages, current input with external shunt, voltages between 0 to 10 V and 0 to 500 V, double output with 0 to 20 mA and 0 to 10 V, accuracy ± 0,5 %, voltage supply 230 VAC (24 VDC)

EZW Transducer for AC power and energy (one phase), acquisition of consumption and delivery, current input of 5 A (in conjunction with current transformer 40 different primary currents up to 4000 A adjustable), voltage 230 V, single output with 0 to 20 mA for the power, 2 impulse output (1 to 500 Imp/kWh) for energy consumption and delivery, internal LCD for energy and power, accuracy ± 0,5% (power) and ± 1% (energy)

EZD Transducer for AC power and energy (three phases), voltage 400/230 V, other characteristics as EZW

ELT-Z Energy counter for one phase AC, current input of 5(20) A, impulse output (1.000Imp/kWh) for energy, internal 6 digit electromechanical counter, accuracy ± 1%, mounting od DIN rail

Pt-MU(-DC) Transducer for Pt100 sensor for 0 to 60 °C, 0 to 100 °C, 0 to 150 °C, 0 to 300 °C or 0 to 600 °C (other values on request, double output with 0 to 20 mA and 0 to 10 V, accuracy ± 0,5 %, voltage supply 230 VAC (24 VDC)

Downloads (10 files)

Wind Direction Sensor
Datasheet
PDF 115 KB
Ambient Temperature Sensor, 10-V-Signal
Datasheet
PDF 79 KB
Wind Speed Sensor
Datasheet
PDF 159 KB
Ambient Temperature Sensor, 4-20-mA-Signal
Datasheet
PDF 79 KB
Ambient Temperature Sensor, Pt100-Signal
Datasheet
PDF 50 KB
Module Temperature Sensor, 10-V-Signal
Datasheet
PDF 74 KB
Module Temperature Sensor, 4-20-mA-Signal
Datasheet
PDF 75 KB
Module Temperature Sensor, Pt100-Signal
Datasheet
PDF 73 KB
Meteorologic Sensors
Overview
PDF 132 KB
Voltage and Current Transducers
Datasheet
PDF 175 KB


Product Selection



Adobe Reader
Most of our documents are Adobe® PDF files. To view these documents properly you need the free Adobe Reader® software.

If you don't have Adobe Reader® already installed on your system the button below will take you to the Adobe® website.